Search results for "Orthodontic Wires"

showing 9 items of 9 documents

Effect of saliva contamination on bracket failure with a self-etching primer: A prospective controlled clinical trial

2010

Introduction The aim of this study was to evaluate in vivo the effect of saliva contamination at different stages of the bonding procedure on the bond failure rate and the adhesive remaining on teeth after debonding brackets bonded with a hydrophilic self-etching primer (Transbond Plus self-etching primer [TSEP], 3M Unitek, Monrovia, Calif). Methods This was a prospective controlled clinical trial. The sample consisted of 46 patients with similar treatment plans and mechanotherapies. Stainless steel brackets (n = 531) were bonded with TSEP. The patients were divided into 2 groups: contamination with saliva before TSEP application and contamination with saliva after TSEP application. In both…

Curing Lights DentalCuspidSalivaOrthodontic BracketsSurface PropertiesDentistryOrthodonticsDental bondingDental Debondingstomatognathic systemIncisorOrthodontic WiresHumansMedicineProspective StudiesSaliva contaminationDental EnamelSalivaDental Debondingbusiness.industryBracketDental BondingStainless SteelResin CementsIncisorClinical trialstomatognathic diseasesSelf etchmedicine.anatomical_structureEquipment FailurebusinessDental AlloysFollow-Up StudiesAmerican Journal of Orthodontics and Dentofacial Orthopedics
researchProduct

Load-deflection characteristics of superelastic and thermal nickel-titanium wires

2011

SUMMARY The aim of this study was to investigate the mechanical properties of superelastic and thermal nickel–titanium (NiTi) archwires for correct selection of orthodontic wires. Seven different NiTi wires of two different sizes (0.014 and 0.016 inches), commonly used during the alignment phase, were tested. A three-point bending test was carried out to evaluate the load–deflection characteristics. The archwires were subjected to bending at a constant temperature of 37°C and deflections of 2 and 4 mm. Analysis of variance showed that thermal NiTi wires exerted significantly lower working forces than superelastic wires of the same size in all experimental tests (P < 0.05). Wire size had a s…

Dental Stress AnalysisTitaniumHot TemperatureMaterials scienceOrthodontic wireMetallurgyBiomechanicschemistry.chemical_elementOrthodonticsElasticityLoad deflectionchemistryNickelNickel titaniumDeflection (engineering)MartensiteThermalOrthodontic WiresComposite materialDental AlloysMechanical PhenomenaTitaniumThe European Journal of Orthodontics
researchProduct

Plaque levels of patients with fixed orthodontic appliances measured by digital plaque image analysis

2011

Introduction A digital plaque image analysis system was developed to objectively assess dental plaque formation and coverage in patients treated with fixed orthodontic appliances. Methods The technique was used to assess plaque levels of 52 patients undergoing treatment with fixed appliances in the Department of Orthodontics at Johannes Gutenberg University in Mainz, Germany. Results Plaque levels ranged from 5.1% to 85.3% of the analyzed tooth areas. About 37% of the patients had plaque levels over 50% of the dentition, but only 10% exhibited plaque levels below 15% of tooth coverage. The mean plaque coverage was 41.9% ± 18.8%. Plaque was mostly present along the gum line and around the or…

MaleAdolescentOrthodontic BracketsSurface PropertiesDental PlaqueGingivaDentistryOrthodonticsOral hygieneImage Processing Computer-AssistedOrthodontic WiresPhotographyHumansMedicineIn patientChildFluorescent DyesOrthodonticsbusiness.industryReproducibility of ResultsOrthodontic bracketsDental plaque formationFemaleFluoresceinbusinessToothSoftwareAmerican Journal of Orthodontics and Dentofacial Orthopedics
researchProduct

Orthodontic load on short maxillary implants with reduced sink depth: an experimental study.

2008

Objective The aim of this study was to investigate experimentally the positional stability and histomorphometric findings of length-reduced temporary anchorage devices (Orthosystem, length: 4 mm) with reduced sink depth. Material and methods For this purpose, four maxillary pre-molars ((2)P(2), (3)P(3)) were extracted from each of four foxhounds. After a 16-week alveolar healing period, 16 implants (four per dog) were inserted into the edentulous areas. Four implants (one per dog) were placed simultaneously in the mid-palatal area. The implants were intentionally submerged to about three-quarters of their length. After a 10-week unloaded implant healing period, the implants in the P3 areas …

MaleImplant surfaceTime FactorsSurface PropertiesBone ScrewsDentistryBone contactDogsOrthodontic AppliancesBone MarrowOsseointegrationAlveolar ProcessMaxillaOrthodontic Anchorage ProceduresOrthodontic WiresMedicineAnimalsOrthodontic Appliance DesignBicuspidDental ImplantsOrthodontic wireOrthodontic Appliance Designbusiness.industryPalateBone screwsEquipment failureMaxillaEquipment FailureImplantBone RemodelingStress MechanicalOral SurgerybusinessClinical oral implants research
researchProduct

MMP-2, MMP-9, and iNOS Expression in Human Dental Pulp Subjected to Orthodontic Traction

2009

Abstract Objective: To test the hypothesis that some metalloproteinases (MMP-2, MMP-9) and inducible nitric oxide synthetase (iNOS) enzymes in dental pulp samples do not vary when subjected to orthodontic treatment. Materials and Methods: Human dental pulps were taken from male and female patients (N=10; age 10–14 years). A straight wire technique was used with nickel-titanium or steel archwires. The increase of pressure applied on teeth was gradual. Five patients were subjected to premolar extractions after 14 months of treatment and one after 24 months. Samples were Bouin-fixed, paraffin-embedded, and afterwards processed for immunohistochemistry using anti-MMP-2, anti-MMP-9, and anti-iNO…

MaleSettore BIO/17 - IstologiaTime FactorsNitric oxide synthetaseAdolescentTooth Movement TechniquesNitric Oxide Synthase Type IIDentistryOrthodonticsMalocclusion Angle Class IIMatrix metalloproteinaseNickelFemale patientOrthodontic WiresPressurePremolarHumansMedicineBicuspidChildTitaniumOdontoblastsMMP-2Orthodontic wirebusiness.industrymedicine.diseaseImmunohistochemistryBiomechanical PhenomenaDental pulpiNOSmedicine.anatomical_structureMatrix Metalloproteinase 9SteelMatrix Metalloproteinase 2ImmunohistochemistryFemaleStress MechanicalTreatment timeMalocclusionMMP-9businessImmunohistochemistry Dental pulp MMP-2 MMP-9 iNOS.Dental AlloysFollow-Up StudiesThe Angle Orthodontist
researchProduct

Toxicity of used orthodontic archwires assessed by three-dimensional cell culture

2006

The aim of the present study was to determine whether used orthodontic wires made of different materials cause toxicity and loss of viability on three-dimensional (3D) cell cultures. Three types of orthodontic wires, stainless steel, Nitinol, and TMA (n = 9) which had been used clinically in fixed appliances for a period of 1 month, were retrieved at random from five patients. Both upper and lower archwires were collected and subjected to two different protocols: to assess toxicity, two pieces of each wire were placed on 3D cell cultures (reconstituted human epithelium); to investigate the possibility of cell damage, the 3-(4,5-dimethylthiazol-2-yl)2,5-diphenyl tetrazolium bromide (MTT) ass…

Malemedicine.medical_specialty3D cell culturesAdolescentH&E stainBiocompatible MaterialsHaematoxylinEpitheliumAndrologychemistry.chemical_compoundToxicity TestsAlloysOrthodontic WiresmedicineHumansMTT assayChildCell damageCells CulturedEosinChemistryStainless Steelmedicine.diseaseSurgeryStainingToxicitycytotoxicityFemaleFormazanorthodontics
researchProduct

Effect of temperature on the orthodontic clinical applications of NiTi closed-coil springs

2013

NiTi spring coils were used to obtain large deformation under a constant force. The device consists on a NiTi coil spring, superelastic at body temperature, in order to have a stress plateau during the austenitic retransformation during the unloading. The temperature variations induced changes in the spring force. Objectives: The aim of this study is to investigate the effect of the temperature variations in the spring forces and corrosion behaviour simulating the ingestion hot/cold drinks and food. Study D esign: The springs were subjected to a tensile force using universal testing machine MTS-Adamel (100 N load cell). All tests were performed in artificial saliva maintained at different t…

Materials scienceElasticidadOrtodòncia616.3OdontologíaOrthodontics:Enginyeria dels materials [Àrees temàtiques de la UPC]Load cellNiTiCorrosionPhysical PhenomenaStress (mechanics)RecoveryMaterials TestingBiomaterials and Bioengineering in DentistryOrthodontic WiresOrthodonticComposite materialSuperelasticitySalivaGeneral DentistryUniversal testing machineElasticitatTemperatureNíquel-titani -- AliatgesCoilsTemperatura:CIENCIAS MÉDICAS [UNESCO]Coil springCiencias de la saludElasticityOrtodonciaNickel-titanium alloysSpringsOtorhinolaryngologySpring (device)Nickel titaniumPseudoelasticityUNESCO::CIENCIAS MÉDICASResearch-ArticleSurgery
researchProduct

The Influence of Friction on Design of the Type of Bracket and Its Relation to OHRQoL in Patients Who Use Multi-Bracket Appliances: A Randomized Clin…

2021

Background and objectives: The aim of this study was to evaluate the influence of friction on design of the type of bracket, patients’ perception of pain and the impact on their oral health-related quality of life. Materials and Methods: A randomized clinical trial was carried out with 90 patients (62.2% women and 37.8% men) with three kinds of fixed multi-bracket appliances: Conventional (GC), fixed multi-bracket low friction (GS) and self-ligating (GA). The VAS (Visual Analogue Scale) was used to determine pain during the first seven days of treatment at different points in time. The patients were also given the OHIP-14 (Oral Health Impact Profile) questionnaire to analyse their oral heal…

Salud bucalFrictionOrthodontic BracketsVisual analogue scaleInvestigación médicaDentistryOdontologíaOral healthArticlelaw.inventionsymbols.namesakeorthodontics; pain; quality of life; low-friction brackets; oral healthQuality of lifeRandomized controlled triallawMaterials TestingOrthodontic WiresHumansOrthodontic Appliance DesignMedicineIn patientpainlcsh:R5-920business.industryBracketAnova testGeneral Medicinelow-friction bracketsBonferroni correctionquality of lifesymbolsoral healthbusinesslcsh:Medicine (General)orthodonticsSoportes ortodóncicos
researchProduct

The use of three-dimensional oral mucosa cell cultures to assess the toxicity of soldered and welded wires

2007

The aim of the present study was to determine whether there is a difference in toxicity and loss of viability of three-dimensional (3D) reconstructed human oral epithelium (RHOE) cell cultures induced by point-welded (PW), laser-welded (LW), and silver-soldered (SiS) orthodontic wires. Three types of soldered stainless steel (SS) wires: PW, LW, and SiS were prepared ( n = 3) and subjected to multiple end-point analysis (MEA). Six pieces were cut from each wire. Each piece was placed on the triplicate cell cultures (RHOE model based on TR 146 cells). After 24 hours of topical exposure, the cell cultures were cut and stained with haematoxylin/eosin. Toxicity was assessed by evaluating the mor…

medicine.medical_specialty3D cell culturesOrthodontic wireEosinCell SurvivalEndpoint DeterminationChemistryMouth MucosatoxicityNegative controlOrthodonticsHaematoxylinSurgeryAndrologychemistry.chemical_compoundmedicine.anatomical_structureCell cultureToxicityOrthodontic WiresmedicineHumanscytotoxicityDental SolderingOral mucosaSevere toxicityThe European Journal of Orthodontics
researchProduct